Step 23 of 37Mechanical

Electrical Wiring

Running new electrical circuits for outlets, lighting, and safety devices. This critical system powers your new living space and must meet strict code requirements.

12-16 hrs
Installation Time
$2,000-4,000
Materials + Labor
Expert
Difficulty Level

Why Proper Electrical Work Matters

Electrical wiring is one of the most safety-critical aspects of any attic conversion. Improperly installed wiring causes thousands of house fires each year. Beyond safety, modern electrical codes exist to ensure your space has adequate power capacity, proper protection devices (AFCIs, GFCIs), and reliable operation. An undersized or overloaded electrical system leads to tripped breakers, dimming lights, and potential hazards. Attic bedrooms have specific requirements including hardwired smoke detectors, AFCI-protected circuits, and proper outlet placement. Getting this right requires planning, permits, and often professional help.

Tools & Materials You'll Need

14/2 & 12/2 Romex
$150-300
Electrical Boxes
$50-100
AFCI Breakers
$100-200
Outlets & Switches
$50-100
Smoke/CO Detectors
$100-200
Wire Staples
$20-30
Wire Strippers
$20-40
Voltage Tester
$25-50

Step-by-Step Guide

1

Plan Electrical Layout

Careful planning prevents problems and ensures code compliance:

Code Requirements for Bedrooms:

  • • Outlets every 12 feet along walls (6 feet max from any point)
  • • At least one switched light outlet (can be switched outlet)
  • • AFCI protection on all bedroom circuits
  • • Hardwired, interconnected smoke detector
  1. Draw floor plan showing outlet and switch locations
  2. Mark lighting fixture positions (recessed lights, ceiling fans)
  3. Identify dedicated circuits needed (HVAC, bathroom, etc.)
  4. Calculate total circuit requirements and panel capacity
  5. Plan wire routes from panel to attic space
  6. Submit plans with permit application if required
2

Run Cables from Panel

Getting power from the panel to the attic is often the hardest part:

Wire Sizing:

  • • 14 AWG for 15-amp circuits
  • • 12 AWG for 20-amp circuits
  • • 10 AWG for 30-amp circuits
  • • Use 12 AWG minimum for long runs

Cable Routes:

  • • Through interior walls (easiest)
  • • Up through closets
  • • Through basement/crawl to exterior wall
  • • Never through return air ducts

Safety First: Always turn off the main breaker before working in the panel. Better yet, have a licensed electrician make panel connections. Even with the main off, the service entrance wires remain live.

3

Install Electrical Boxes

Proper box installation before drywall makes finishing easier:

Standard Box Heights:

  • Outlets: 12-18 inches from floor to bottom of box
  • Switches: 48 inches from floor to bottom of box
  • Above counters: 6 inches above counter surface
  1. Mark box locations on studs according to plan
  2. Use new-work boxes that nail to studs (before drywall)
  3. Position boxes so front edge will be flush with drywall
  4. Install ceiling boxes for lights and fans (use fan-rated boxes for fans)
  5. Drill holes through studs for wire runs (center of stud)
  6. Install nail plates where wires pass within 1-1/4" of stud edge
4

Wire Outlets and Switches

Rough wiring connects all boxes before drywall goes up:

  1. Run cable from panel to first box on each circuit
  2. Continue daisy-chaining to subsequent outlets
  3. Run switch legs from switches to fixture boxes
  4. Leave 8-12 inches of wire extending from each box
  5. Staple cable within 12" of boxes and every 4 feet
  6. Label circuits clearly at each box

AFCI Requirement: Install AFCI breakers for all bedroom circuits. Alternatively, use the first outlet in each circuit as a combination AFCI/GFCI device that protects the entire downstream circuit.

Pro Tip: Take photos of all wiring runs before drywall. This documentation helps future repairs and proves code compliance to inspectors.

5

Install Smoke and CO Detectors

Life safety devices are code-required in sleeping areas:

Smoke Detector Locations:

  • • Inside each bedroom (on ceiling or within 12" of ceiling on wall)
  • • Outside bedroom area in hallway or stair landing
  • • All detectors must be interconnected (when one sounds, all sound)
  • • Hardwired with battery backup

CO Detector Requirements:

  • • Required if home has attached garage or fossil fuel appliances
  • • Within 10 feet of bedroom doors
  • • Can be combination smoke/CO units

Interconnection: Use 14/3 wire between smoke detectors. The red wire carries the interconnect signal. When one detector senses smoke, it sends voltage on the red wire, triggering all connected units.

Pro Tips

  • Add more outlets than minimum code requires - future you will thank present you
  • Install USB outlets near bed locations - eliminates the need for charging adapters
  • Consider dimmer switches for bedroom lighting - better sleep environment
  • Run low-voltage wiring (ethernet, coax) now while walls are open - much harder later
  • Use a 20-amp circuit for the HVAC unit - mini-splits require dedicated power

Frequently Asked Questions

Do I need AFCI breakers for an attic bedroom?

Yes, current electrical code (NEC) requires Arc-Fault Circuit Interrupter (AFCI) protection for all bedroom circuits, including outlets, lighting, and smoke detectors. AFCIs detect dangerous arcing conditions that standard breakers miss, preventing electrical fires. You can use AFCI breakers at the panel or combination AFCI/outlet devices at the first outlet in each circuit.

How many outlets do I need in an attic bedroom?

Code requires outlets so that no point along a wall is more than 6 feet from an outlet. In practice, this means an outlet every 12 feet along walls. Kitchen counter rules don't apply to bedrooms. For comfort, consider more outlets than minimum: beside each side of the bed, at the desk area, and near furniture positions. Plan for USB charging needs too.

Can I run electrical wiring myself or do I need an electrician?

This depends on local regulations. Some jurisdictions allow homeowners to do their own electrical work with proper permits and inspections. Others require licensed electricians. Even if DIY is permitted, electrical work is dangerous and code requirements are complex. Many homeowners rough in wire routes and box locations, then hire an electrician for connections and panel work. Always get permits and inspections.

What size electrical panel do I need for an attic conversion?

An attic bedroom typically requires 2-4 new circuits: one or two for outlets (15A or 20A), one for lighting (15A), and possibly one for HVAC. If your panel has capacity, you may not need to upgrade. However, if your panel is full or undersized (100A or less), you may need a panel upgrade or subpanel. Have an electrician perform a load calculation before starting.